Radon Testing Summary
RADON-TEST-V3.jpg
Lab Test Chamber
Figure 3:  Radon Testing
Lab generated radon levels
averaging 40.0 pCi/L were reduced
to 0.2 pCi/L in 5 hours of Plasma
Vortex Operation.  Mfg. quality
enhancements with streamlined
components should improve
performance. 
(1) Upstream of Vortex Tube. 
(2) Downstream of Vortex Tube.
(3) Extraction Gap Exhaust Zone. 
(4) Bottom inlet of Updraft Module. 
(5) Top of Updraft Outlet.
Figure 4:  2012 Super Moon Tide Chart and a Four Day Radon Test
Radon-Tide-graph.jpg

Figure 4:  2012 Super Moon Tide Chart

and a Four Day Radon Test

Placing a tide chart over a radon test showed high and low radon closely matching high and low tides.  As the heaviest gas in the atmosphere, it was still surprising to see tidal gravity impacting radon gas readings inside an upscale residential finished basement.  This was the compelling discovery that forced recognition that radon was an aggressive contaminant, needing mechanical controls to keep it out of indoor living space.

Radon Gas fluctuates with the weather and tidal gravity.  It is therefore difficult to differentiate between natural fluctuations, and changing environmental conditions.   This makes testing radon cumbersome.  Laboratory testing was designed to isolate the radon inside a circulation chamber.  Radon was mechanically generated by pumping air through naturally radioactive shale from a local road cut.

Radon-Generator.jpg

Figure 5:  Stark Shale

Radon Generator

Chamber.Annotations01252019.png
Figure 6:  Radon Isolation / Circulation Chamber
radon-chamber-circulation.jpg
Figure 7:  96 Hour
Radon Test
48hr-extraction.jpg

RADON TESTING SUMMARY:

The reduction of the ~40.0 pCi/L radon level to 0.2 pCi/L in 5 hours is significant.  EPA published guidance indicates that radon reduction below 2.0 pCi/L is difficult to maintain with state of the art reduction methods.  Hopefully, manufacturing streamlined components will improve vortex extraction performance.  The fact that radon is about 8 times heavier than fresh air makes centrifugal separation viable.  The inventor had observed Steel Mill cyclone separators removing steel grit from rolling mill cooling water.  It is interesting to note that steel is also about 8 times heavier than water.